<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.peertechzpublications.org/assets/xsl/oaitohtml.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:mml="http://www.w3.org/1998/Math/MathML" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
										<responseDate>2026-04-04T10:00:38Z</responseDate>
										<request verb="GetRecord" metadataPrefix="oai_dc" identifier="oai:www.peertechzpublications.org:10.17352/2581-5407.000048">https://www.peertechzpublications.org/oai-pmh</request><GetRecord><record>
								<header>
									<identifier>oai:www.peertechzpublications.org:10.17352/2581-5407.000048</identifier>
									<datestamp>2022-10-20</datestamp>
									<setSpec>PTZ.GJCT:VOL8</setSpec>
								</header>
								<metadata>
									<oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:mml="http://www.w3.org/1998/Math/MathML" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
										<dc:title>
										Investigation of the effectiveness of ECOLAB ’Drape ArmourTM’ Radiation Protection in limiting eye-lens doses of healthcare personnel exposed to ionizing radiation during gastroenterology - interventional radiology procedures
										</dc:title><dc:creator>Fulvio IM Fucilli</dc:creator><dc:creator> Giuseppe Di Giovanni</dc:creator><dc:creator> Alessandro Mastrorocco</dc:creator><dc:creator> Matteo Ninni</dc:creator><dc:creator> Piero Loprete</dc:creator><dc:creator> Isa De Crudis</dc:creator><dc:creator> Massimiliano Marano</dc:creator><dc:creator> Antonio Santomauro</dc:creator><dc:creator>Fabio Fucilli</dc:creator><dc:description>&lt;p&gt;Objectives: To investigate the efficiency of the ECOLAB “Drape ArmourTM” device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Methods: Eyelens doses measured with eye-lens dosimeters calibrated in terms of equivalent dose at 3 mm depth ( Hp(3) ) were collected and analyzed since 2016 along with the irradiation parameters (Dose Area Product - DAP).&amp;nbsp;&lt;/p&gt;&lt;p&gt;The eye-lens doses received during the four-month trial, have been compared with doses normally received, in the same conditions of irradiation, in the absence of the protection drape.&lt;/p&gt;&lt;p&gt;Results: During the period of use of Drape ArmourTM, the average dose to the eye lens was estimated to be 0.73 mSv (St.dev = 0.40 mSv). The average dose to the eye lens, measured in the same four-month period, across different years from 2017 to 2021, was equal to 1.30 mSv (st. dev = 0.35 mSv).&lt;/p&gt;&lt;p&gt;Conclusions: Results suggest the effectiveness of Drape ArmourTM in containing the doses to the eye lens.&lt;/p&gt;&lt;p&gt;Keypoint: Limiting eye-lens doses to a maximum value of 20 mSv/year is a real challenge, especially in interventional radiologic facilities. The use of suitable radio-opaque drapes may help healthcare workers involved in such facilities. The aim of the work is to evaluate the efficiency of the ECOLAB “Drape ArmourTM” sterile mono-use drape.&lt;/p&gt;</dc:description>
										<dc:publisher>Global Journal of Cancer Therapy - Peertechz Publications</dc:publisher>
										<dc:date>2022-10-20</dc:date>
										<dc:type>Clinical Techniques</dc:type>
										<dc:identifier>https://doi.org/10.17352/2581-5407.000048</dc:identifier>
										<dc:language>en</dc:language>
										<dc:rights>Copyright © Fulvio IM Fucilli et al.</dc:rights>
									</oai_dc:dc>
								</metadata>
							</record></GetRecord>
						</OAI-PMH>